Difference between revisions of "ADC max1027"

From ArmadeusWiki
Jump to: navigation, search
m (Installation)
(add picture)
Line 1: Line 1:
Instructions to install and use the onboard ADC (MAX1027)
+
Instructions to install and use the MAX1027 ADC. '''This device is an option of the [[APF9328]] boards.''' To know if you have one on your board, take a look at the connectors side:<br><br>
 +
[[Image:APF9328_with_MAX1017.jpg]]
  
 
==Introduction==
 
==Introduction==

Revision as of 10:03, 5 September 2008

Instructions to install and use the MAX1027 ADC. This device is an option of the APF9328 boards. To know if you have one on your board, take a look at the connectors side:

File:APF9328 with MAX1017.jpg

Introduction

The Max1027 is a 8 channels 10 bits A/D converter with an integrated temperature sensor.
The 8 inputs voltage range is 0 - 3,3V. Don't try to put higher voltage on ADC inputs !!
The i.MXL SPI_1 interface is used to communicate with the device.
For the Linux kernel, the Max1027 is considered as a Hardware Monitoring device. For the moment only a low speed interface (/sys) is available: the eight channels and the temperature are updated every 10ms.

Installation

  • From the top directory:
$ make linux-menuconfig
  • Then select in Device Drivers->SPI support->Freescale iMX SPI controler driver (builtin not module !!)

SPI Linux Config.png

  • Then select in Device Drivers->Hardware Monitoring Support->MAX1027 sensor chip (Module)

HWMonitor Linux Config.png

MAX1027 Linux Config.png

  • Once the new config saved, rebuild your image
$ make

and copy hwmon.ko and max1027.ko driver to your target or reflash your rootfs.

  • On the target, the driver can be started like this:
# insmod /lib/modules/drivers/hwmon/hwmon.ko
# insmod /lib/modules/drivers/hwmon/max1027.ko
  • or like this if you reflashed your rootfs:
# modprobe max1027

Usage

Several interfaces in /sys/bus/spi/are created in order to

  • read the 8 inputs (inx_input). Result in mV
  • read the temperature (temp_input). Result in deg celsius
  • modify the default configuration (config and conv)

An input can be read like that

# cat /sys/bus/spi/devices/spi1.0/in0_input

The temperature can be read like that

# cat /sys/bus/spi/devices/spi1.0/temp1_input

The two configurations files allow direct access to the corresponding register in the MAX1027. For more details, take a look at the datasheet

Other languages:

English Flag.svg English  •  French Flag.svg Français